THE FENTANYL TEST IS THE WORLD'S FIRST HARM REDUCTION TEST THAT HAS THE CUTOFF LEVEL OF 1ng/mL, THAT DOES NOT REQUIRE DILUTION OF THE SUBSTANCE, AND PRESERVES ANY TESTED SUBSTANCES, 100% FOR EVIDENCE OR USE.
Cutoff Level: 1ng/mL
These strips can be used on any surface or substance (including gels, pastes, liquids, powders, crushed pills, clothing, and human hair) to determine if Fentanyl is present. The Fentanyl Harm Reduction test can be used on any surface, such as a couch, bed, car, countertop, etc. It will also test other illicit drugs such as cocaine, meth, etc. to confirm if the drug is laced with Fentanyl.
The Fentanyl Test is proud to bring a newly FDA-cleared line of Fentanyl tests and solutions in the effort to help solves the struggles of the Fentanyl epidemic.
Intended use
The 1ng / mL Harm Reduction is a one-step lateral flow immunoassay device for the detection of drug residues on suspected surface or in powder. The Harm Reduction device detects Fentanyl at the cutoff of 1 ng/ml.
This product is intended for forensic use only and is not for use in diagnostic procedures.
The Harm Reduction provides only preliminary drug test results. For a quantitative result or for a confirmation of a presumptive positive result obtained by the Harm Reduction, a more specific alternative method such as GC/MS or LC/MS must be used.
Summary and Explanation
Illegal drug consumption contributes to many accidents, injuries and medical conditions.
AllSource Harm Reduction is developed to detect drug residues on suspected surface or in powder. It is designed to integrate the collection of sample and lateral flow immunoassay screen testing in one single device.
Test principle
The Harm Reduction is based on a competitive immunoassay procedure in which drug derivatives immobilized on the membrane compete with the drug(s) which may be present for limited antibody binding sites on the colored colloidal gold antibody conjugate. During testing, drug residue is collected by the collection pad, and migrates across the membrane when buffer is added. If no drug is present on the surface, the colored colloidal gold antibody conjugate will bind to the drug derivatives on the membrane to form visible bands at specific test regions. Therefore, the presence of a purple-red band at a specific test region indicates a negative result.
If any drug(s) is (are) present on the surface, it competes with the immobilized drug conjugate for limited antibody binding sites of the colored colloidal gold conjugate. When sufficient amount of drug is present, the drug will saturate the antibodies, and the colored colloidal gold conjugate cannot bind to the drug derivative on the membrane. Therefore, the absence of a purple-red band at the test region indicates a presumptive positive result for that particular test.
A control band at the control region (C) indicates the test has performed properly. This control band should always appear regardless of the presence of drug or metabolite.
Reagents
The Harm Reduction contains one membrane strip and a collection pad. The strip consists of a membrane immobilized with drug-protein conjugates and corresponding specific drug monoclonal antibody colloidal gold conjugate pad, a sample pad and an absorbent pad.
Collection Pad: The collection pad consists of an absorbent material.
Buffer: The buffer dissolves and/or extracts the drug from suspected residues.
Materials Provided
Each Harm Reduction kit contains:
1 Package Insert.
1 Test Strip (individually packaged in a foil pouch with a desiccant).
1 Buffer Vial ( 0.15 ml per vial)
Warnings and Precautions
Product Storage
The Harm Reduction pouch should be stored at room temperature (15°-30°C). Do not open pouch until ready to perform the assay.
Test Procedure
Most Harm Reduction tests for deadly Fentanyl are a scam. Most display no cutoff level at all, and all but ours requires dilution of the substance. Our test is the only test on Earth to offer:
* CUTOFF LEVEL TO 1ng/mL
* NO DILUTION REQUIRED
BTNX RAPID RESPONSE'S CUTOFF: 200ng/mL (fatal) and requires full substance dilution
DANCESAFE CUTOFF: 10ng/mL (fatal) and requires full substance dilution